-67%

Testing Commissioning Protection Relays By Osama Abdel Aziz

$15.00

File size: 2.85 GB
Media Type: Online Course
Delivery Time: 1-12 hours.
Content proofWatch here!

Description

Testing Commissioning Protection Relays By Osama Abdel Aziz – Instant Download!

Testing Commissioning Protection Relays
Commissioning RED 670 ( Line Differential Protection 87L – Distance Protection 21) and REF 615 Overcurrent Relay

What you’ll learn

  • Introduction to Protection Relays with Transmission line feeders
  • The Different Between Protection Schemes with Transmission line feeders
  • Install PCM Program and REF 615 Connectivity Package
  • Overcurrent Relay REF 615 Hardware Configuration
  • How change The Polarity of CT By using PCM Program
  • REF 615 Application Configuration
  • REF 615 Measurement Function Blocks
  • REF 615 Trip Logic Philosophy
  • Line Differential Distance Relay RED 670
  • RED 670 Connectivity Package
  • RED 670 Binary Input and Output
  • Transmute Current for Remote End Substation
  • RED 670 Application Configuration
  • Line Differential Function Block
  • Line Differential Trip Philosophy
  • Distance Protection Introduction
  • Power Swing and Fuse Failure Supervision
  • Trip Philosophy with Zone 1
  • Trip Philosophy with Zone( 2-3-4)
  • IT Received Trip From Remote End Substation
  • Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
  • Current Reversal and Weak- End Feed Protection Function
  • Switch Onto Fault Function Block
  • Auto Re-closure
  • SAS Alarm ,Measurement and Disturbance Recorder

Requirements
The basic electrical principles

Description
Dear fellows,

This is the most comprehensive online training of Testing Commissioning Protection Relays . Here you will learn all thing about RED 670 and REF 615

RED 670 and REF 615 are the most common type of Protection Relays that you will find on the electrical network, due to their effectiveness and simplicity.

This course will give you an appreciation of how to commissioning this type of Protection Relays

we will go through the following topics

  • Introduction to Protection Relays with Transmission line feeders
  • The Different Between Protection Schemes with Transmission line feeders
  • Install PCM Program and REF 615 Connectivity Package
  • Overcurrent Relay REF 615 Hardware Configuration
  • How change The Polarity of CT By using PCM Program
  • REF 615 Application Configuration
  • REF 615 Measurement Function Blocks
  • REF 615 Trip Logic Philosophy
  • Line Differential Distance Relay RED 670
  • RED 670 Connectivity Package
  • RED 670 Binary Input and Output
  • Transmute Current for Remote End Substation
  • RED 670 Application Configuration
  • Line Differential Function Block
  • Line Differential Trip Philosophy
  • Distance Protection Introduction
  • Power Swing and Fuse Failure Supervision
  • Trip Philosophy with Zone 1
  • Trip Philosophy with Zone( 2-3-4)
  • IT Received Trip From Remote End Substation
  • Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
  • Current Reversal and Weak- End Feed Protection Function
  • Switch Onto Fault Function Block
  • working theory of Auto Re-closure Function
  • SAS Alarm ,Measurement and Disturbance Recorder

Who this course is for:

  • Anyone interested in electrical engineering
  • Electrical undergraduates
  • Electrical graduates
  • Workers in the electrical power utility

Course content

Introduction

  • Introduction
  • The Different Between Protection Schemes

Overcurrent Relay REF 615

  • REF 615 manual
  • REF 615 Hardware Configuration
  • REF 615 Hardware Configuration 2
  • Polarity For CT
  • REF 615 Application Configuration
  • REF 615 Application Configuration 2
  • REF 615 Trip Logic
  • REF 615 Measurement

Line Differential Protection RED 670

  • RED 670 Connectivity Package
  • RED 670 Binary Input and Output
  • RED 670 CT and VT
  • Transmute Current for Remote End Substation
  • RED 670 Application Configuration
  • Signal Matrix For Analog Input SAMI
  • Line Differential Function Block
  • Line Differential Output Signal
  • Line Differential Trip

Distance Protection RED 670

  • Distance Protection Introduction
  • Phase Selection Function Block FDPSPDIS
  • Power Swing
  • Fuse Failure Supervision
  • Distance Schema
  • Trip Philosophy with Zone 1
  • Trip Philosophy with Zone( 2-3-4)
  • IT Received Trip From Remote End Substation
  • Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
  • Communication Scheme Logic
  • Current Reversal and Weak- End Feed Protection
  • Question about Current Reversal
  • Weak- End Feed Logic
  • Switch Onto Fault
  • Auto Re-closure
  • Auto Re-Closure 2
  • SAS Alarm ,Measurement and Disturbance Recorder

Instructor

Testing Commissioning Protection Relays By Osama Abdel Aziz
Osama Abdel Aziz
Bachelor of Electrical engineering (power & machines).

Hello,

I’m Osama Abdel Aziz

Electrical Power Systems Engineer

I Have

Bachelor of Degree in Electrical Power and Machines Engineering

i am work naw as protection enginner in EETC company

I share with you my academic and practical experience

I I find a real joy in teaching :).

Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I’m grateful For

Excellent knowledge and delivering the theory and practical concept with such an ease.

Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.

Testing Commissioning Protection Relays By Osama Abdel Aziz, what is it included (Content proof: Watch here!):

  • 01 Introduction
  • 02 Overcurrent Relay REF 615
  • 03 Line Differential Protection RED 670
  • 04 Distance Protection RED 670